Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Methods Mol Biol ; 2511: 307-319, 2022.
Article in English | MEDLINE | ID: covidwho-1941385

ABSTRACT

Severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) has been identified as the causative agent of COVID-19. Accurate detection of SARS-CoV-2 infection is not only important for management of infected individuals but also to break the chain of transmission. Although the polymerase chain reaction (PCR) is the gold standard for diagnosis of acute SARS-CoV-2 infection, there are a number of limitations of these assays, which include the inability to detect past infection and decline in sensitivity 14 days post-symptom onset. There are several serology tests developed for the detection of SARS-CoV-2 antibodies including high-throughput serology platforms and lateral flow immunoassays. These tests should be evaluated for their performance to meet local regulations acceptance criteria. To optimize the diagnostic algorithm for SARS-CoV-2, this protocol describes the evaluation of serological antibody testing using various automated serology platforms and lateral flow immunoassays. This protocol was evaluated in both serum and plasma samples. The sample preparation, procedure, and data analysis are described. The protocol can be adapted for any serological testing.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19/diagnosis , COVID-19 Testing , Humans , Immunoassay/methods , Sensitivity and Specificity
2.
PLoS One ; 17(2): e0262442, 2022.
Article in English | MEDLINE | ID: covidwho-1854992

ABSTRACT

In late December 2019, pneumonia cases of unknown origin were reported in Wuhan, China. This virus was named SARS-CoV2 and the clinical syndrome was named coronavirus disease 19 (COVID-19). South Africa, despite strict and early lockdown has the highest infection rate in Africa. A key component of South Africa's response to SARSCoV2 was the rapid scale-up of diagnostic testing. The Abbott SARS-CoV2 assay detects IgG antibodies against the Nucleocapsid (N) protein of the SARS-CoV2 virus. This study undertook to validate and evaluate performance criteria of the Abbott assay and to establish whether this assay would show clinical utility in our population. Positive patients (n = 391) and negative controls (n = 139) were included. The Architect-i and Alinity-i systems were analyzers that were used to perform the SARS-CoV-2 IgG assay. In-house ELISA was incorporated into the study as a confirmatory serology test. A total of number of 530 participants was tested, 87% were symptomatic with infection and 13% were asymptomatic. When compared to RT-qPCR, the sensitivity of Architect and Alinity SARS-CoV2 assays was 69.5% and 64.8%, respectively. Specificity for Architect and Alinity assays was 95% and 90.3%, respectively. The Abbott assay was also compared to in house ELISA assay, with sensitivity for the Architect and Alinity assays of 94.7% and 92.5%, respectively. Specificity for Abbott Alinity assays was 91.7% higher than Abbott Architect 88.1%. Based on the current findings testing of IgG after 14 days is recommended in South Africa and supports other studies performed around the world.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Immunoglobulin G/blood , SARS-CoV-2/isolation & purification , Adult , Aged , Aged, 80 and over , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/epidemiology , COVID-19/virology , Enzyme-Linked Immunosorbent Assay , Female , Follow-Up Studies , Humans , Immunoglobulin G/immunology , Male , Middle Aged , Prognosis , Retrospective Studies , South Africa/epidemiology , Young Adult
3.
J Immunol Methods ; 496: 113096, 2021 09.
Article in English | MEDLINE | ID: covidwho-1349521

ABSTRACT

Serology or antibody tests for COVID-19 are designed to detect antibodies (mainly Immunoglobulin M (IgM) and Immunoglobulin G (IgG) produced in response to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS CoV-2) infection. In this study, 30 lateral flow immunoassays were tested using serum or plasma from patients with confirmed SARS CoV-2 infection. Negative serological controls were accessed from a well-characterised bank of sera which were stored prior to February 2020. Operational characteristics and ease of use of the assays are reported. 4/30 (13%) of kits (Zheihang Orient Gene COVID-19 IgG/IgM, Genrui Novel Coronavirus (2019-nCoV) IgG/IgM, Biosynex COVID-19 BSS IgG/IgM, Boson Biotech 2019-nCoV IgG/IgM) were recommended for SAHPRA approval based on kit sensitivity. Of these, only the Orientgene was recommended by SAHPRA in August 2020 for use within the approved national testing algorithm while the remaining three received limited authorization for evaluation. All kits evaluated work on the same basic principle of immunochromatography with minor differences noted in the shape and colour of cartridges, the amount of specimen volume required and the test duration. Performance of the lateral flow tests were similar to sensitivities and specificities reported in other studies. The cassettes of the majority of kits evaluated (90%) detected both IgG and IgM. Only 23% of kits evaluated contained all consumables required for point-of-care testing. The study highlights the need for thorough investigation of kits prior to implementation.


Subject(s)
Antibodies, Viral/isolation & purification , COVID-19 Serological Testing/instrumentation , COVID-19/diagnosis , Immunoassay/instrumentation , Reagent Kits, Diagnostic/statistics & numerical data , Antibodies, Viral/blood , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/immunology , COVID-19/virology , COVID-19 Nucleic Acid Testing/statistics & numerical data , COVID-19 Serological Testing/statistics & numerical data , Humans , Immunoassay/statistics & numerical data , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin G/isolation & purification , Immunoglobulin M/blood , Immunoglobulin M/immunology , Immunoglobulin M/isolation & purification , Point-of-Care Testing/statistics & numerical data , RNA, Viral/blood , RNA, Viral/isolation & purification , SARS-CoV-2/genetics , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , Sensitivity and Specificity
4.
PLoS One ; 16(6): e0252317, 2021.
Article in English | MEDLINE | ID: covidwho-1280618

ABSTRACT

Severe Acute Respiratory Syndrome-Coronavirus 2 (SARS-CoV-2) has been identified as the causative agent for causing the clinical syndrome of COVID -19. Accurate detection of SARS-CoV-2 infection is not only important for management of infected individuals but also to break the chain of transmission. South Africa is the current epicenter of SARS-CoV-2 infection in Africa. To optimize the diagnostic algorithm for SARS-CoV-2 in the South African setting, the study aims to evaluate the diagnostic performance of the EUROIMMUN Anti-SARS-CoV-2 assays. This study reported the performance of EUROIMMUN enzyme-linked immunosorbent assay (ELISA) for semi-quantitative detection of IgA and IgG antibodies in serum and plasma samples targeting the recombinant S1 domain of the SARS-CoV-2 spike protein as antigen. Samples were collected from 391 individuals who had tested positive for SARS-CoV-2 and 139 SARS CoV-2 negative controls. Samples were stratified by number of days' post-PCR diagnosis and symptoms. The sensitivity of EUROIMMUN IgG was 64.1% (95% CI: 59.1-69.0%) and 74.3% (95% CI: 69.6-78.6%) for IgA and the specificity was lower for IgA [84.2% (95% CI: 77-89.2%)] than IgG [95.2% (95% CI: 90.8-98.4%)]. The EUROIMMUN Anti-SARS-CoV-2 ELISA Assay sensitivity was higher for IgA but low for IgG and improved for both assays in symptomatic individuals and at later timepoints post PCR diagnosis.


Subject(s)
COVID-19 Serological Testing/methods , Immunoglobulin A/blood , Immunoglobulin G/blood , Adult , Aged , Aged, 80 and over , COVID-19 Nucleic Acid Testing/methods , Enzyme-Linked Immunosorbent Assay/methods , Female , Humans , Male , Middle Aged , Point-of-Care Testing , Sensitivity and Specificity , South Africa
SELECTION OF CITATIONS
SEARCH DETAIL